P550c Operation Manual
6 Operating the system
www.pearpoint.com | 179
5 (Applies to Structured and WinCan surveys only) Fill out the details required for your chosen survey
standard.
- The current field is highlighted in gray.
- Mandatory fields are highlighted in yellow.
Tip: Press the Super tab button to quickly tab through the mandatory fields only. You can
fill in the other fields later; see page 203.
- Press the  arrow keys to move through all the header fields.
- Fields with buttons have a drop-down menu. For drop-down menu shortcuts, see page 233.
- Press Save to save the form.
6 (Applies to Structured and WinCan surveys only) Press the panel button to start recording.
7 Now carry out the video inspection. Use the controller tools to:
- Pause the recording, rotate the camera, use a sonde, mute an audio commentary, and highlight pipe
defects. See page 181.
- Take a photo. See page 182.
- Add an observation. See page 223.
8 Press the panel button or Stop button, and press Yes to confirm, to stop the recording.