61
ENGLISH |
MODE5 CONFIG
COSFI REC:ON
Enable (ON) or disable (OFF) automatic COSFI recovery when it is below
COSFI MIN (dry running)
With COSFI RECOVERY, the control panel attempts to automatically recover
an electric pump that is in the dry running alarm state (COSFI read < COSFI
minimum)
MODE5 CONFIG
REC TIME:2m
Recovery time for automatic deactivation of the dry running alarm.
The control panel attempts automatic recovery after the set time, and then
doubles it on each subsequent cycle (e.g. 2 min, 4 min, 8 min ...), up to the
maximum recovery time (see the next parameter).
Default 2 min Range 0-10 min Step 1 min
MODE5 CONFIG
MAX REC T:60m
Maximum recovery time for automatic deactivation of the dry running
alarm.
The control panel attempts automatic recovery up to the set maximum val-
ue (e.g. every 60 min).
Default 60 min Range 0-120 min Step 1 min
Conguring MODE 6
SELECT
MODE CONFIG
Press the key to conrm the choice and enter the submenu.
9
MODE CONFIG
MODE:1
Press the key to enter the submenu and change mode.
6 9
MODE:6
Press the or key to select mode 6
(from modes 1 to 6)
Press the
key to conrm the choice of MODE:6
Press the
key to continue with the conguration
9
MODE CONFIG
SETUP
Press the key to enter the mode 6 conguration submenu
9
MODE6 CONFIG
RUN:EMPTYING
Set the operating mode:
– EMPTYING (empty the collection tank)
– FILLING (ll the tank)
– PRESSUR. (pressurise the domestic/industrial system)
MODE6 CONFIG
SENS L:OFF
Enable (ON) or disable (OFF) the capacitive level sensors
MODE6 CONFIG
IN1:RUN
Set the rst input (IN1):
– STOP (input enabled to stop the rst pump)
– RUN (input enabled to start the rst pump)
– OFF (input disabled)
Continued