EasyManua.ls Logo

PEDROLLO VSP - User Manual

PEDROLLO VSP
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
PEDROLLO S.p.A.
Via E. Fermi, 7 37047 – San Bonifacio (VR) - Italy
Tel. +39 045 6136311 – Fax +39 045 7614663
e-mail: sales@pedrollo.com – www.pedrollo.com
MADE IN ITALY
VSP
INVERTER ON BOARD FOR ELECTRIC PUMP
CONTROL
EN Correct disposal of WEEE (DIRECTIVE 2012/19/EU)
code 12039901Q01 00/22

Questions and Answers

  • S
    sara03Aug 22, 2025
    What to do if PEDROLLO Water Pump VSP shows a “DRY RUN” alarm on start-up?
    • A
      Adam JohnsonAug 22, 2025
      If your PEDROLLO Water Pump VSP displays a “DRY RUN” alarm at start-up, check the COSFI MIN setting in the CONF.MOTOR menu. For the 400V three-phase model, ensure the pump rotates correctly. Also, verify the connection and operation of the flow sensor connected to IN1, ensuring IN1 is OFF. Note this is a self-resetting alarm with repeated attempts for REC TIME.
  • D
    David LoweSep 4, 2025
    What to do if PEDROLLO Water Pump VSP shows a “CIRCU.OPEN” alarm on pressure transducer at start-up?
    • S
      Stephanie WilsonSep 4, 2025
      If the PEDROLLO Water Pump VSP goes to protection due to “CIRCU.OPEN” alarm on the pressure transducer upon start-up, check that the transducer is correctly connected and that the cables are not damaged. Also, check the transducer state. Note that this is a self-resetting alarm.
  • J
    johnsonchrisSep 3, 2025
    Why does my PEDROLLO Water Pump VSP show a “PFC.IN.LOW” alarm on start-up?
    • B
      balljasmineSep 3, 2025
      If the PEDROLLO Water Pump VSP goes to protection due to input undervoltage alarm “PFC.IN.LOW”, check if the input voltage has decreased, or if the VSP is incorrectly connected to a power system (e.g., 230V instead of 400V). Also, inspect the condition of the power cables. Note that this is a latching alarm.
  • K
    Kathleen WilliamsSep 1, 2025
    Why does my PEDROLLO Water Pump VSP show a “MIN.VOLTAGE” alarm on start-up?
    • R
      Rachel DanielsSep 1, 2025
      If the PEDROLLO Water Pump VSP goes to protection due to input undervoltage alarm “MIN.VOLTAGE”, check if the input voltage has decreased, or if the VSP is incorrectly connected to a power system (e.g., 230V instead of 400V). Also, inspect the power cables for any issues. Note that this is a latching alarm.
  • C
    Christopher MilesAug 31, 2025
    Why does my PEDROLLO Water Pump VSP show a “PFC.IN.HIGH” alarm on start-up?
    • K
      Kristen DavenportAug 31, 2025
      If the PEDROLLO Water Pump VSP goes to protection due to input overvoltage alarm “PFC.IN.HIGH”, check if the input voltage has increased, or if the VSP is incorrectly connected to a power system (e.g., 400V instead of 230V). Also, inspect the power cables for any issues. Note that this is a latching alarm.
  • B
    Bianca RosalesAug 29, 2025
    Why does my PEDROLLO Water Pump VSP show a “MAX.VOLTAGE” alarm on start-up?
    • C
      Chelsea RussellAug 29, 2025
      If the PEDROLLO Water Pump VSP goes to protection due to input overvoltage alarm “MAX.VOLTAGE”, check if the input voltage has increased, or if the VSP is incorrectly connected to a power system (e.g., 400V instead of 230V). Also, inspect the power cables for any issues. Note that this is a latching alarm.
  • J
    Joanna CollinsAug 27, 2025
    Why does my PEDROLLO Water Pump VSP show a “MAX CURRENT” alarm on start-up?
    • M
      Michael ReedAug 27, 2025
      If the PEDROLLO Water Pump VSP goes to alarm mode for “MAX CURRENT” protection upon start-up, you should first check the maximum current setting in the CONF.MOTOR menu. Also, verify that the motor being used is working correctly. Note that this is a latching alarm.
  • A
    Ashley HicksAug 27, 2025
    How to reset a non-latching alarm on a PEDROLLO Water Pump?
    • J
      Jose OwensAug 27, 2025
      To reset a non-latching alarm on the PEDROLLO Water Pump, follow these steps: * Press the button. * Look for the message 'CLEAR ERROR? (TYPE OF ALARM *)' on the display. * Press the key to definitively reset the alarm.
  • E
    Ethan WashingtonAug 25, 2025
    What to do if PEDROLLO VSP Water Pump is in automatic mode but the pump is not enabled?
    • A
      annemartinezAug 26, 2025
      If the PEDROLLO Water Pump VSP is in automatic mode but the pump is not enabled, check the configuration of the inputs IN1, IN2, and the PRESSURE TRANSDUCER in the ADVANCED PARAMETERS MENU. Also, check that the inputs are working correctly, such as the pressure switch connected to IN1, IN2, or the PRESSURE TRANSDUCER.
  • B
    Brandon CastroAug 23, 2025
    How to fix LCD ERROR alarm on my PEDROLLO VSP Water Pump?
    • M
      Mark JonesAug 23, 2025
      If the display of your PEDROLLO Water Pump does not switch on or shows an "LCD ERROR” alarm, check that the FLAT cable is correctly connected and is not damaged.

Summary

General Information and Safety Rules

Symbols Explained

Visual symbols used in the manual and their meanings.

Safety Warnings and Emergency Procedures

General Warnings and Precautions

Important safety advice for product installation and usage.

Emergency Stop Procedure

How to perform an emergency stop and ensure safety.

Product Description and Technical Data

Product Features Overview

Key features and characteristics of the VSP inverter.

Technical Specifications

Details on voltage, frequency, IP rating, and environmental conditions.

Use Limitations and Controls

Operating Limitations and Overload

Defines use limitations, pressure, temperature, and overload auto-limitation.

Product Components and Controls

Identification of VSP parts and explanation of control panel buttons and display.

Installation and Display Symbols

Display Symbols and Indicators

Meaning of various indicator lights and symbols on the VSP display.

Installation Requirements and Diagrams

Conditions for VSP installation and typical installation configurations.

Product Positioning and Pressure Sensor

Product Positioning Guidelines

Instructions for securely mounting the VSP unit.

Pressure Sensor Functionality

Explanation of the pressure sensor's role and working principle.

Electrical Connections and Diagrams

Electrical Connection Safety

Crucial safety precautions for connecting the VSP to the power supply.

Connections Diagram

Visual representation of the VSP's internal terminal boards for wiring.

Terminal Board Configurations

Power Supply Terminal Board

Details on the power terminals for mono-phase and three-phase VSP units.

Inputs;Outputs Terminal Board Details

Comprehensive explanation of all input and output terminal functions.

Parallel Operation and Start-Up

Parallel Pump Setup

Instructions for connecting multiple pumps to work in parallel.

Start-Up and Pump Priming

Steps for initial system start-up and the essential pump priming process.

Functioning Parameters

Operating Parameters and Setpoints

Viewing Operating Parameters

Methods to display various operational parameters on the VSP's alphanumerical display.

System Pressure Setpoint Adjustment

Procedure for increasing or decreasing the system pressure setpoint.

Advanced Parameters Menu

Parameter Categories Overview

Listing and brief description of the main advanced parameter configuration groups.

Advanced Parameter Details: Configuration

Language and Basic Configuration Settings

Setting VSP language and fundamental parameters like pressure and dry run.

Transducer and Input;Output Configuration

Configuring pressure sensors, external inputs, and output relay functions.

Advanced Parameter Details: Motor Settings

Motor Current and Rotation

Adjusting motor rated current and setting rotation direction.

Motor Frequency and Cosfi Settings

Configuring minimum/maximum frequency and dry run cosfi values.

Advanced Parameter Details: Sensor Configuration

Pressure Transducer Setup

Selecting pressure transducer types and defining their operating ranges.

Analogue Inputs Mode

Choosing the type of analogue input for pressure transducer signals.

Advanced Parameter Details: Input;Output Configuration

External Input Configuration

Setting up external inputs for operation, flow sensing, or alarms.

External Output Configuration

Enabling and configuring the VSP's external output relays for status signals.

Advanced Parameter Details: Group Configuration

VSP Operating Modes

Configuring single or parallel operation, including MASTER/SLAVE modes.

Parallel Operation Types

Selecting modes for alternating or modulating parallel VSP operation.

Advanced Parameter Details: Test and Restore

Electric Pump Test Mode

Using test functions to check system pressure, frequency, and current.

Default Parameter Restoration

Procedure to reset VSP parameters to their initial default configuration.

Alarms

Alarm Descriptions (Part 1)

Detailed explanations for alarms like EXT ALARM, DRY RUN, and MAX CURRENT.

Alarms (Continued)

Alarm Descriptions (Part 2)

Detailed explanations for alarms like PHASE ERROR, INU ERROR, and LCD ERROR.

Troubleshooting

Alarm Reset and Basic Troubleshooting

Procedure to reset alarms and check basic configurations for pump enablement.

Troubleshooting Specific Alarms

Diagnosing issues related to DRY RUN, SHORT CIRCUIT, and PHASE ERROR alarms.

Troubleshooting (Continued)

Troubleshooting Over;Undervoltage and Display Issues

Resolving problems related to voltage fluctuations, communication, and display errors.

Maintenance

Disposal

Declaration of Conformity

Troubleshooting (Continued)

Troubleshooting PFC Errors and Overheating

Diagnosing PFC module errors, voltage issues, and temperature-related alarms.

PEDROLLO VSP Specifications

General IconGeneral
Liquid temperature0 °C to +40 °C
Maximum ambient temperature+40 °C
Insulation classF
Frequency50 Hz
Pump typeSubmersible
TypeVSP
InstallationSubmersible
MaterialsStainless steel AISI 304

Related product manuals