ECP300 EXPERT
Pag. 22
USE AND MAINTENANCE MANUAL
Rev. 0
1
-
12
ECP300 EXPERT PANEL FUNCTIONS
- Signaling with LED icons of the plant status.
- Electronic control with wide LED display and easy to use buttons.
- Display and adjustment of cold room temperature accurate to 0.1 °C.
- Display of evaporator temperature from parameter.
- System control activation/deactivation.
- Alarm signaling: probe errors, minimum and maximum temperature alarm, compressor
protection (man in cold room alarm in preset models).
- Evaporator fans control.
- Automatic and manual defrost control (static, heating element).
- Direct or pump-down control of motor compressor unit (selectable by terminal block
connection in preset models).
- Room light activation, via panel key or door switch
- Auxiliary relay with activation configurable by parameter.
- RS485 for connection to TeleNET industrial supervision network.
- Paramet access with Password (4 different selectable restriction levels).
- General magnetothermic circuit breaker accessible from the front panel, which cuts the
general power supply.
- Adjustable motor circuit breaker for compressor protection accessible from the front panel
(in preset models).
- Differential magnetothermic Id=30mA dedicated to room light accessible from the front
panel (in preset models).
CHAPTER 4: FUNCTIONS
4.1
CHAP. 4 - Functions

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pego ECP300 EXPERT VD Series and is the answer not in the manual?

Pego ECP300 EXPERT VD Series Specifications

General IconGeneral
BrandPego
ModelECP300 EXPERT VD Series
CategoryControl Panel
LanguageEnglish

Related product manuals