1. Types of Fuel
The type of fuel you are burning will dictate how often you
have to clean your repot.
If the fuel you are burning has a high dirt or ash content, it
may be necessary to clean the repot more than once a day.
Poor quality fuel will cause clinkers to form in the repot. A
clinker is formed when dirt, ash or a non-burnable substance
is heated to 2000°F (1093°C) and becomes glass-like. See
section D following for more details on fuels with high ash
content.
Shock and Smoke Hazard
Turn dial control to OFF, let appliance complete-
ly cool and exhaust blower must be off. Now
you can unplug appliance before servicing.
Smoke spillage into room can occur if appliance
is not cool before unplugging.
Risk of shock if appliance not unplugged before
servicing appliance.
CAUTION
Cleaning or Inspection
Frequency Daily Weekly Monthly Yearly
Firepot Every 3 bags of fuel OR X
Ash Removal from Firebox Every 5 bags of fuel or more
frequently depending on ash
build-up
OR X
Glass When clear view of repot
becomes obscure
OR X
Hopper Every 25 bags of fuel OR X
Exhaust Path, Drop Tube and Behind
Baf es
Every 25 bags or more fre-
quently depending on ash
build-up
OR X
Door Handle & Gasket Inspection Prior to heating season OR X
Blower, Convection Every 25 bags or more fre-
quently depending on operat-
ing environment.
OR X
Blower, Exhaust More frequently depending on
the fuel type
OR X
Firebox - Prepare for Non-Burn Season At end of heating season OR X
Venting System Every 3 tons or more fre-
quently depending on the fuel
type
OR X
B. Quick Reference Maintenance Chart
Follow the detailed instructions found in this
section for each step listed as referenced in
the chart below.
NOTICE: These are recommendations. Clean more frequently if you encounter heavy build-up of
ash at the recommended interval or you see soot coming from the vent. Not properly
cleaning your appliance on a regular basis will void your warranty.
A. Proper Shutdown Procedure C. General Maintenance
4 Maintaining & Servicing the Appliance