NXT Multi Language
Programming Parame ters and Ranges
Gallons Liters
Valve Address 12341234 1 2 12341234
Select Language x x x xxxxxxxx x x xxxxxxxx
System Size x x x x x
Regen Type x x x xxxxxxxx x x xxxxxxxx
Valve Type x x x xxxxxxxx x x xxxxxxxx
Regenerant Flow x x x xxxxxxxx x x xxxxxxxx
Remote Signal Start x x x xxxxx x xxxx
Display Format x x x xxxxxxxx x x xxxxxxxx US - Gallons EU - Metric-Liters
Unit Capacity x x xxxxx x x xxxxxxxx 1 - 9900000 Grains 1 - 198000 gCaCO3
Capacity Safety Factor x x xxxxx x x xxxxxxxx
Feed Water Hardness x x xxxxx x x xxxxxxxx 1 - 199 Grains/Gallons 1 - 1999 mgL
Trip Point 1 x 0 - 997gpm 0 - 3997 Lpm
Trip Delay 1 x 30 - 99 Seconds 30 - 99 Seconds
Trip Point 2 x Trip Point 1 + 1 - 998 gpm Trip Point 1 + 1 - 3998 Lpm
Trip Delay
2 x 30 - 99 Seconds 30 - 99 Seconds
Trip Point 3 x Trip Point 2 + 1 - 999 gpm Trip Point 2 + 1 - 3999 Lpm
Trip Delay 3 x 30 - 99 Seconds 30 - 99 Seconds
Regeneration Day Override x x x xxxxx x xxxxxxxx
Regeneration Time
x o o ooooo o o oooooooo 12:00 a.m. - 11:59 p.m. 00:00 - 23:59 Hour
Cycle 1 x x x xxxxxxxx x x xxxxxxxx
Cycle 2 x x x xxxxxxxx x x xxxxxxxx
Cycle 3 x x x xxxxxxxx x x xxxxxxxx
Cycle 4 x x x xxxxxxxx x x xxxxxxxx
Cycle 5 x x x xxxxxxxx x x xxxxxxxx
Auxiliary Relay x x x xxxx u xxx u x xxxxxxxx
Aux Relay Output Start
c c c cccccccc c c cccccccc
Aux Relay Output End
c c c cccccccc c c cccccccc
Chemical Pump x x xxxx u u xxxxxxxx
CPO Aux Relay Volume
c c ccccc c cccccccc 1 - 999 gallons 0001 - 9999 Liters
CPO Aux Relay Time
c c ccccc c cccccccc 00:00:01 - 02:00:00 00:00:01 - 02:00:00
Flow Meter x x xxxxx x xxxxxxxx
Generic
x x xxxxx x xxxxxxxx
Maximum Flow Rate
a a aaaaa a aaaaaaaa 20 - 2000 GPM 20 - 2000 LPM
Add _ _ _ Gallons or Liters
a a aaaaa a aaaaaaaa 1 - 255 Gallons 001 - 255 Liters
Every _ _ _ Pulses
a a aaaaa a aaaaaaaa 552 - 1552 - 1
Notes
o -
u -
c -
a -
System Type
If Generic Flow Meter is chosen, then programming parameters will be viewed.
Regeneration Time will only be viewed if Regeneration Day Override is used.
If Auxiliary Relay is Enabled
then Chemical Pump Relay will not be viewed or if Chemical Pump Relay is Enabled then Auxiliary R elay will not be viewed.
All Relay Output parameters programming will be viewed if Enabled.
00:00:01 to Total Regeneration Time - 1
Start Time + 1
to Total Regeneration Time
Enabled, Disabled
O, 1 - 99
00:00:00 - 04:00:00
O, 00:00:00 - 04:00:00
1" 1.5" Paddle or Turbine, 2" Paddle, 3" Paddle, Generic
O, 00:00:00 - 04:00:00
O, 00:00:00 - 04:00:00
O, 00:00:00 - 04:00:00
Enabled, Disabled
2750, 2815, 2850, 2900, 3150, 3900, Stager
Downow, Upow, Upow Fill
First
O, 00:00:01 - 01:39:00
0- 50%
6
Series
7
Alternating
9
Alternating
Time Clock, Metered Delayed, Metered Immediate
Programming Parameter Ranges
4
Time
Clock
4
Metered
Immediate
4
Metered
Delayed
5
Interlock
14
Demand
Recall
1 thru 4
English, Espanol, Portugues
, Deutsch, Francais
1 thru 4
2750/2850/2900S UPPER & 2900S LOWER
POWERHEAD ASSEMBLY
37
35
31
41
39
32
19
7
6
30
36
32
40
20
38
33
22
52
12
21
13
44
16
14
15
14
17
16
46
25
16
26
1
42
23
46
2
11
4
3
5
6
7
10
19
32
28
29
18
6
11
43
9
8
32
24
61501-3200NXT-2_Page2_REVA
27
45
47
48
51
49
50
12 • Fleck 3200 NXT Fleck 3200 NXT • 13