EasyManua.ls Logo

Pentair iCHLOR - System Specifications; Wiring Instructions

Pentair iCHLOR
124 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
20
English
Troubleshoong (Connued)
Problem Possible Cause Correcve Acon
FLOW LED is red. Pump fails to provide sucient water ow. Check for correct operaon of the pump,
i.e., loss of pump prime or clogged strainer
baskets.
Closed valves. Check and correct all valve alignments.
Dirty lter. Follow lter cleaning procedures.
Obstrucon in the Chlorinator cell. Remove cell for inspecon. Follow cleaning
procedures. See “Electrolyc Cell Cleaning
iCHLOR unit does not have
power.
Fuse in Power Center is open. Replace AC fuse, located at boom of Power
Center.
No A/C power to Power Center. Verify me clock is providing 220VAC to Power
Center when acve.
Transformer leads not wired correctly in
Power Center.
Verify transformer leads wired to AC source by
referring to wiring diagram decal on inside of
Power Center cover.
System Specicaons - 230 VAC
Circuit Protecon: Two pole 20AMP devise at the electrical panel.
Model KPC 30-250 (complete system)
Input: 50/60Hz, 220-240 VAC, 220W, 1 Amp. Output: 15 - 28 VDC @ 5.2 Amp Max.
Water ow: 6m³/h (25GPM) - Max ow: 24m³/h (105GPM) - Max Pressure: 5Bar (75PSI)
iCHLOR AC Wiring Instrucons :
- When using the iCHLOR Salt Chlorinator and an IntelliFlo pump (or variable speed pump) with a Pentair IntelliPool Automaon
System, please read the IntelliPool installaon manual - Secon ‘Desinfectant Connecon - Alternave Salt Chlorinator.
- When using the iCHLOR Salt Chlorinator with the ‘Pentair ControlPro Filtraon Managerand a Variable Speed pump, please
read the ‘Pentair ControPro Filtraon Manager’ installaon manual.

Table of Contents

Related product manuals