7
English
Secon 1
iCHLOR Control Panel
SALT STATUS LED INDICATORS
The iCHLOR salt level checks the pool water daily and displays the levels as follows:
GREEN LED: Good Salt. The pool water salt level is between 2800ppm and 4500ppm, and the iCHLOR is producing chlorine.
iCHLOR salt LED should always be showing GREEN level for opmum results. Ideal salt level is 3400ppm.
GREEN LED (FLASHING): Salt level is above 4500ppm. Chlorine is being produced but the salt level is too high which increases
the risk of corrosion and deterioraon of pool equipment and surfaces in and around the pool. Pool water needs to be
drained and relled 300 mm at a me unl the salt level is below 4500ppm.
RED LED: Low salt. The water salt level is below 2800ppm. The iCHLOR will be producing chlorine at a reduced eciency.
It is recommended to add salt (*)
FLASHING RED LED: Very low salt. The water salt level has dropped below 2600ppm. The iCHLOR will not produce chlorine
unl salt is added. The iCHLOR is o. (*)
(*) Aer every salt addion, pump should run for at least 24 hours for proper diluon. Salinity readings should only be taken
aer the 24 hour diluon period.
STATUS LED INDICATORS
CELL: SHOWS THE STATUS OF THE iCHLOR
GREEN FLASHING: The iCHLOR needs to be inspected. The blades may be calcied. The iCHLOR will not be producing chlorine.
GREEN: iCHLOR is performing good and producing chlorine
NO LIGHT: The iCHLOR is o and not producing chlorine. It may be in an o cycle of the sanizing process and will return
on in due course.
RED: The iCHLOR is in “Standby” mode (system o, no chlorine generaon) due to cold weather condion. The iCHLOR will
resume chlorine producon once the water temperature goes above 11 ° C.
FLOW: THIS LIGHT INDICATES THE STATUS OF THE WATER FLOWING THROUGH THE iCHLOR
RED: Insucient water ow through the iCHLOR, no chlorine is being produced.
GREEN: Sucient water owing through the iCHLOR, chlorine is being produced.
OUTPUT LED INDICATORS
The three (3) LED indicators display as a bar graph to show in increments, the percentage of me the chlorine is produced
per hour of pump run me. In BOOST mode, these LEDs blink from boom to top.
Note: If no LEDs are lit, the output is set to 0% and the iCHLOR Salt Chlorinator is not producing chlorine.
• 0% 0 LED lit - No chlorine produced - iCHLOR Salt Chlorinator is o.
• 33.3% 1 LED lit - Produces chlorine 33% of each hour of pump run me.
• 66.6% 2 LED lit - Produces chlorine 66% of each hour of pump run me.
• 100% 3 LED lit - Produces chlorine 100% of each hour of pump run me.