OPERATING THE PUMP 6/25
SET MAXIMUM SPEED RPM
The maximum speed can be set from 1900 RPM to 3450 RPM (default is 3450). Use this setting
to set the maximum running speed of the IntelliFlo
®
VSF Variable Speed and Flow pump.
1. Check that the green power LED is on.
2. Press menu.
3. Press select to select “Settings”.
4. Use the up or down arrows to scroll to “Min/Max”.
5. Use the up or down arrows to scroll to “Set Max Speed”.
6. Press select to change. The cursor will appear in the first number column.
7. Press up or down arrows to change the maximum speed setting from 1900 till 3450 RPM.
8. Press save, to save. Press back to exit. To cancel, press back to exit without saving.
Note: Maximum speed will limit priming speed, except in one case. If the maximum speed
is set below the lowest available Priming Speed (2400 RPM) then the pump will exceed the
maximum speed while the priming feature is running. This prevents the pump from having
trouble priming if the maximum speed is set this low. If this is a problem, priming can be
disabled in the priming menu (see “Priming” section later on this manual).
SET MINIMUM FLOW RATE (m³/h)
The minimum programmed flow rate can be set from 5.5 m³/h to 19 m³/h.
1. Check that the green power LED is on.
2. Press menu.
3. Press select to select “Settings”.
4. Use the up or down arrows to scroll to “Min/Max” and press select.
5. Use the up or down arrows to scroll to “Set Minimum Flow”.
6. Press select to change the setting. The cursor will appear in the first number column.
7. Press the up or down arrows to edit the minimum flow rate setting from 5.5 m³/h till 19
m³/h.
8. Press save, to save. To cancel, press back to exit edit mode without saving.
9. Press back to exit.
17