IntelliFlo
®
VSD Pump Menus
Press MENU button to access menus
MAINSCREEN
(page 14)
SETTINGS
(1-16) Default: ADDRESS 1
(hr:mm) Default: 12:00 AM
Set AM /PM
AM /PM
24 hr.
Fahrenheit - Default:
Celsius
(1-5) Default 3
(450 RPM - 1700 RPM) - Default: 450 RPM
(1900 RPM - 3450 RPM) - Default: 3450 RPM
Pump Address
Set Time
Tem perature Unit
Screen C ontrast
Language
Set Min Speed
Set Max Speed
PASSW ORD
Passw ord Time Out (1 min. - 6 hours) Default:10 minutes
Disabled/Enabled - Default: Disabled
Enter Passw ord (xxxx) Default: 1234
(page 19)
SPEED 1-8
Speed 1 (1-4)
M anual
Schedule
Egg Timer
Set Speed - Default: MANUAL
Set Speed
Set Start Time
Set Stop Time
Set Speed
Time
(page 20)
EXT CONTROL
Program 1
Speed - Default: 750 RPM
Speed - Default: 1500 RPM
Program 2
(page 20)
FEATURES
Quick Clean
Set Speed (1100 -3450 RPM) Default: 3450 RPM
Time (1 min. to 10 hrs.) Default: 10 minutes
Time Out Duration (1 min. to 10 hrs.) Default: 3 hours
Time Out
(page 22)
PRIMING
DISABLED/ENABLED
(1 min. to 30 min. hrs.) Default: 11 minutes
M AX PRIMING TIME
(page 24)
ANTI FR EEZE
Disabled / Enabled - Default: Enabled
Program 3
Speed - Default: 2350 RPM
Speed - Default: 3110 RPM
Program 4
English, French, Germ an, Dutch, Spanish, Italian,
Portuguese - Default: English
Speed 5 (5-8)
Schedule
Set Speed
Set Start Time
Set Stop Time
Disabled
Default: Disabled
Default: Enabled
(1 - 100% ) Default: 1
PRIMED SENSITIVITY
(1 second - 10 minutes) Default: 20 seconds
PRIMING DELA Y
DISABLED/ENABLED
SET SPEED
40° F - 50° F (4. C - 10° C) Default: 40° F (4. C)
PUMP TEM PERATURE
Set Speed (750 RPM - 3450 RPM) Default 1000 RPM
English