28
Connecting the IntelliFlo
®
pump to a IntelliPool
System
The IntelliFlo
®
pump can be controlled by an IntelliPool system via the RS-485 communication
cable.
WARNING - Switch OFF main system power to the IntelliPool Control Center before making any
connections.
To connect the IntelliFlo
®
pump RS-485 communication cable to the IntelliPool circuit board:
1. Open the front of the IntelliPool control center.
2. Remove the red protective panel
3. Route the two conductor cable up through the control center grommet opening located on the
right side, and up through the bus connector to the motherboard.
4. Strip back the cable conductors 6 mm (1/4”). Insert the wires into the screw terminals. Secure
the wires with the screws. Be sure to match the color coding of the wires; YELLOW to COM
– and GREEN to COM + .
5. Close the control center.