5.1.2 Additional Warning Messages
5.1.3 Alarm Messages
In the following cases, the chlorinator shuts down and the alarm and acoustic alarm LED is
activated (automatic reset once the fault is solved):
5. TROUBLESHOOTING
Message: Causes: Action required:
ORP or PPM value is ashing
The ORP or free chlorine probe
are balanced in automatic
mode. When the probe is
balanced, the value remains set.
None.
pH value is ashing
The pH probe is balancing.
When the probe is balanced, the
value remains set.
None.
Value - -
0
(Water
temperature) is ashing
The value of the water
temperature is under 15
0
.
Consider the use of a winter
hibernator product.
Filter time
The equipment has switched
off before the time set in semi-
automatic.
Restart the ltering cycle.
Message Causes Action Required
"NO WATER FLOW"
Excess gas in the
electrolysis cell. It may have
occurred because the pump
has shut-down. The gas is
hydrogen gas which is highly
ammable.
The piping should be
drained to eliminate gas or
accumulated water. Check
the pump.
Sensor cable of the cell is
incorrectly connected or
broken.
Check the sensor cable
(white cable)
Cell sensor is dirty.
Clean.
See maintenance.
No water ow Check the water system
"SHORT CIRCUIT"
The cell is incorrectly
connected.
Check wiring.
Metal debris in the cell.
Turn off the equipment and
remove the metal debris
from the plates