Posi-Chlor® Salt Water Chlorinator Owners Manual
32
5. TROUBLESHOOTING
Message Causes Action Required
"OPEN CIRCUIT"
Cell is incorrectly
connected.
Check the cell connection
and ensure that cables and
connection terminals are in
good condition.
Cell is damaged or
completely worn down.
Check the condition of the
cell electrodes, and replace
it if any damage is observed.
Swimming pool water with
very low salt concentration.
Ensure that the water has
salt and that it is dissolved.
"Chl. Error"
Chlorine probe is incorrectly
connected or damaged
Check the cabling of the
probe and the probe itself.
Check 5.1. It can work in
manual mode if necessary.
Water contains very low
redox potential.
Leave the equipment to
chlorate in manual mode for
at least 2 hours.
Check the chemical balance
of the water. (Appendix 1)
The equipment does not
have a probe and is in
"automatic mode".
Install a ORP or Free
Chlorine probe, or congure
"manual" mode.