25
Performance data
Model
ULTRATEMP-E 8 ULTRATEMP-E 10 ULTRATEMP-E 12 ULTRATEMP-E 15
Heating power
Air
24°C 70%RH
Water
20°C
W 8210 10190 12430 15950
Power input W 1550 1960 2302 3009
COP - 5.3 5.2 5.4 5.3
Heating power
Air
70%RH
Water
26°C
W 7200 9100 11300 14500
Power input W 1532 1996 2306 3021
COP - 4.7 4.8 4.9 4.8
Heating power
Air
24°C 70°RH
Water
13°C
W 8450 10600 13010 16140
Power input W 1625 2078 2455 3104
COP - 5.2 5.1 5.3 5.2
Fan
Speed RPM 900 900 800 800
Power W 80 80 140 140
Power supply 230V- 1~ - 50Hz
Minimum water flow m³/h 4 5 5 5
Noise level
A 1m 53 dB(a) 54 dB(a) 54 dB(a) 54 dB(a)
A 10m 33 dB(a) 34 dB (a) 34 dB(a) 34 dB(a)
COP = Coefficient of Performance
RH = Relative Humidity