(Table 5, contd)
The system must be fault free for 40 hours before the system will reset to zero. If the fault is intermittent, and returns within the 40 hours, then the
repeat inducement time will be triggered.
The override can only be used once.
Repeat Inducement
time
None 48 minutes 20 minutes Shut down or idle
Until fault heals
Cycling the keyswitch
will give 20 minutes of
full power
Inducement None None None
Notification None Emission malfunction
lamp will be on solid
Emission malfunction
lamp will flash
Emission malfunction
lamp will flash
The stop lamp will
activate
Emission malfunction
lamp will flash
Contact your Perkins dealer or your Perkins Distributor at level 1 warning, do not let the fault develop.
World-Wide DEF Level Warnings
Two options are available but only one option will be
enabled.
• The low-level warning lamp will operate when DEF
level reaches the trigger point of below 19 percent.
• At Level 1 the low-level warning lamp in the DEF
gauge will illuminate and the emission malfunction
lamp will be on solid.
• At Level 2 the low-level warning lamp for the DEF
is active and the emission malfunction lamp will
flash.
• At Level 3 all level 2 warning are operating, plus
the stop lamp will become activate. The engine will
shut down or will only operate at 1000 RPM.
Filling the DEF tank will remove the warning from the
system.
Table 6
World-Wide DEF Level Option 1
-
Normal operation Initial indication Level 1 Level 2 Level 3
Inducement Trigger Above 19 percent Below 19 percent Below 12.5 percent 0 Percent reading Empty tank
Inducement None None None 25 percent torque de-
rate
Shut down or idle only
Notification None Low-level lamp
illuminated
Low-level lamp
illuminated
Emission malfunction
lamp on solid
Low-level lamp
illuminated
Emission malfunction
lamp flashing
Low-level lamp
illuminated
Emission malfunction
lamp flashing
Stop lamp on solid
Table 7
World-Wide DEF Level Option 2
-
Normal operation Initial indication Level 1 Level 2 Level 3
Inducement Trigger Above 19 percent Below 19 percent Below 12.5 percent 6 Percent reading 0 Percent reading
(continued)
SEBU8732 39
Features and Controls
Selective Catalytic Reduction Warning System