Engine Stopping
i05406628
Stopping the Engine
NOTICE
Stopping the engine immediately after the engine has
been working under load, can result in overheating
and accelerated wear of the engine components.
Avoid accelerating the engine prior to shutting down
the engine.
Avoiding hot engine shutdowns will maximize turbo-
charger shaft and bearing life. Also, selective catalytic
reduction component life.
Note: Individual applications will have different
control systems. Ensure that the shutoff procedures
are understood. Use the following general guidelines
in order to stop the engine.
1. Remove the load from the engine. Reduce the
engine speed to low idle. Allow the engine to idle
for 5 minutes in order to cool the engine.
2. Stop the engine after the cool down period
according to the shutoff system on the engine and
turn the ignition keyswitch to the OFF position. If
necessary, refer to the instructions that are
provided by the OEM.
Note: Some applications the engine will continue to
operate after the keyswitch is turned to the OFF
position. The engine will operate for a short time in
order to allow engine components to cool.
3. Allow at least 2 minutes after the engine has
stopped before you turn the battery disconnect
switch to OFF. Disconnecting the battery power too
soon will prevent purging of the DEF fluid lines
after the engine is shut down. Also, during the 2
minutes the engine electronic control module is
active, storing information from the engine and
aftertreatment sensors.
Delayed Engine Shutdown (if
Equipped)
The delayed engine shutdown allows the engine to
run for a time after the engine start switch is turned to
the OFF position in order to cool the system
components. The engine start switch key may be
removed.
Note: There may be regulations that define the
requirements for the operator and/or support
personnel to be present when the engine is running.
Leaving the machine unattended when the engine
is running may result in personal injury or death.
Before leaving the machine operator station, neu-
tralize the travel controls, lower the work tools to
the ground and deactivate all work tools, and
place the lever for the hydraulic lockout control in
the LOCKED position.
Leaving the engine unattended while running may
result in property damage in the event of a
malfunction.
Note: An authorized dealer can change the maximum
run time value up to 30 minutes but the default setting
is 10 minutes.
An override can be enabled so that the delayed
engine shutdown will not operate. Overriding delayed
engine shutdown may reduce engine and system
component life. The override is operated by the
keyswitch.
At any time during a delayed engine shutdown, the
engine start switch may be turned to the ON position.
The engine may be placed back into service.
i05195199
Emergency Stopping
NOTICE
Emergency shutoff controls are for EMERGENCY
use ONLY. DO NOT use emergency shutoff devices
or controls for normal stopping procedure.
The OEM may have equipped the application with an
emergency stop button. For more information about
the emergency stop button, refer to the OEM
information.
Ensure that any components for the external system
that support the engine operation are secured after
the engine is stopped.
72 SEBU8732
Engine Stopping
Stopping the Engine