14
108 Workshop Manual, TPD 1458E, issue 3 - Perkins Confidential: Green
400 Series
Wiring diagram 15 amp alternator - 403C-11
Wiring diagram maximum circuit resistance
The resistance of battery cables 1, 2 and 3 must not exceed 0.0018
³.
Note: If a glow signal is not used - it is still necessary to connect terminal 19 and 17 on the switch.
(1) Max current draw for standard oil pressure switch is 0.42 amps (5 Watt lamp max).
Circuit
Cable
number
Circuit current
Maximum circuit
resistance
Maximum cir-
cuit
volt drop
Remarks
Alternator
charging
14 amp (2 cyl)
15 amp (3 cyl)
0.036
³ (2 cyl)
0.033
³ (3 cyl)
0.5 Volt
See Glow Plugs
Circuit
Starter motor
solenoid
15.75 amp 0.04
³ 0.63 Volt
See Glow Plugs
Circuit
STD glow plugs
(via glow signal)
(Peak max)
26 amp (2 cyl)
39 amp (3 cyl)
0.0192
³ (2 cyl)
0.0128
³ (3 cyl)
0.5 Volt
1 Alternator warning lamp
2 Regulator
3 Alternator
4 Battery
5 Starter motor
6 Oil pressure warning lamp
7 Oil pressure switch
(1)
8 Water temperature warning lamp
9 Thermostat switch
10 Fuse
11 Key switch
12 Glow signal
13 Glow plugs
14 Solenoid switch
15 A delayed fuse can be fitted if required
= Diode. Capacity: Current 3 amp. Reverse Voltage: 600V. (This is mandatory).
Y
R
B
B
S
AC
17
30
50 19
Sb
Sb
G
2
1
3
4
5
11
12
13
10
6
8
9
7
14
15

Table of Contents

Other manuals for Perkins 404C-22T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Perkins 404C-22T and is the answer not in the manual?

Perkins 404C-22T Specifications

General IconGeneral
BrandPerkins
Model404C-22T
CategoryEngine
LanguageEnglish

Related product manuals