8
Workshop Manual, TPD 1458E, issue 3 - Perkins Confidential: Green 71
400 Series
6 Connect a suitable clean fuel reservoir (1), which has a tap and contains approximately 0,2 litres (¼ pint) of
clean fuel, to the fuel injection pump inlet.
7 Put a suitable waste fuel (3) container below the pipe neck and open the tap, if set correctly the fuel should
flow.
Note: The fuel reservoir should be approximately 152 mm (6 in) above the fuel injection pump.
8 Turn the crankshaft slowly until the fuel flow reduces to a drop which falls every 7 - 10 seconds. This is then
the timing point.
9 Use the value shown by the timing mark (2) with the injection timing tables on page 69.
Continued