perma PRO -12-
PRESS Short Short
Long > 4 sec. until
the display content
changes completely
Long > 4 sec. until
the display content
changes completely
BUTTON
MODE
SAVE
gure11
ON/OFF
SELECT
gure12
MODE
SAVE
gure11
ON/OFF
SELECT
gure12
FUNCTION
Selection
incurrent
display
Changingof
values
Movestonewmenuand
savesselectedvalues
Returnstooriginalmenu
withoutsavingchanges
chart3,gure11,gure12
5.4 Control Buttons
Therearetwopush-buttonsonthecontrolunit(refertogure8)whichcanbeusedforamenu-guidedchangeof
thesettings.
WiththeMODE/SAVEbutton(refertofigure11),youcanreachtheconfigurationmenu,changethemode
andsavethemodifiedsettingsforfurtheroperation.
WiththeON/OFFSELECTbutton(refertofigure12)youcandothefollowing:turnlubricatorOn/Off,increase
dischargeperiod(Days,Weeks,Months-eachtimeyoupressthebuttonincreasesthedischargeperiodby
onecalendarunit),changePROLCunitsize,activateMP-6outletsandsetPIN.
6. Operation and Control
6.1 Preparations
Priortotheinstallationofthelubricator,thelubricationpointandthecompleteconnectiontubemustbe
sufficientlyprelubricatedwiththesamelubricantthatthePROLCunitcontains.Forthis,perma-tecoffersa
400glubricationcartridgeforgreasepresseswiththecorrespondinglubricant(referto“Accessoriesand
SpareParts”).
WheninstallingthepermaPRO,thesuppliedperma-tecmountingdeviceshouldbeused.
Thelubricanttubemustbeinstalledandmountedcorrectly.Thelengthofthelubricanttubemaynotexceeda
maximumof5metersandthetubemustbeaperma-tecproduct.
PleasecheckifthethreadofthepermaPRO(G3/8)correspondstotheconnectionthreadofthelubrication
point.Ifthisisnotthecase,youcanorderacorrespondingreducerorotherpartsfromthepermaaccessory
range.
FortheinitialsettingintooperationofapermaPRO,thepumpsysteminthedriveunitispre-lledwith
SF04fromperma’sstandardrangeoflubricants.Anexceptionismadewithregardtolubricantsforthefood
industry.Acompletedischargeofthispumpllingisguaranteedafterapprox.10discharges(carryoutadditional
discharges,ifnecessary).
6.2 Prior to Operation
Checkallpartsofthelubricatorforobviousdamages!
IsthenewPROLCunitlledwiththerequiredlubricant?
Didyouinsertanewbatteryset?
Didyouremoveprotectioncover,discandplugfromdriveunit(seechapter1.2)?
Didyouassembleandmountallofthepartscorrectlyandtightly?