7 719 Sewing foot holding current B 0 - 50 40
720 Cutting holding current B 0 - 50 40
721 Feed converter holding current C 0 - 50 40
722 Acceleration ramp: C 1 - 50 50
1 = flat / 50 = steep
723 Brake ramp: C 4 - 50 50
1 = flat / 50 = steep
729 Start delay after B 0 - 2550 120
lowering the presser foot [ms]
730 Lift delay B 0 - 2550 0
for presser foot after seam end [ms]
731 Stitch count delay for end backtacks C 0 - 2550 70
732 Holdoff time for cutting C 0 - 2550 30
after simple end backtack [ms]
733 Holdoff time from C 0 - 200 30
switch-on feed reverse
to speed start [ms]
739 Holdoff time for speed C 0 - 2550 200
after start backtack or
stitch condensation [ms]
740 Stitch count delay for end backt. [ms] C 0 - 2550 60
760 Stitch count to bobbin thread monitor A 0 - 50000 1000
(machine stop in needle lowered pos.)
761 Extension B 0 - 2550 0
Thread tension release/
thread puller [ms]
791 Stitch count delay C 0 - 2550 30
for start backtacks [ms]
797 Hardware test: ON = on / OFF = off B OFF - ON OFF
798 User level: A 0 - 255 0
0 = User level A
1 = Mechanic level B
11 = Service level C
Group
Parameter
Setting
range
Set
value
User
level
Description