Input
64
Group
Gruppe
Parameter
Parameter
Description
Bedeutung
Setting
range
Set value
600
607 Cold start (RESET)
With this function the control unit
carries out a cold start (RESET) with
which the data is reset. After this func-
tion has been selected, the machi-
ne must be switched off and then on
again.
608 Setting zero points
With this function and the adjustment
gauge, the zero points for the X/Y-drive
unit can be set. (stepping motor cor-
rection values for the reference points
REFX, REFY). The access code is
required for this adjustment.
609 Setting the button clamp centre X
This function is used to set the cen-
tre of the button clamp in X-direction.
When entering the function, the ma-
chine moves to the current clamp cen-
tre, after which it is possible to move
to the right or left edge of the button
clamp, depending on the set limits (pa-
ram. "023"). A correction can be made
with the plus/minus keys. The relocati-
on value is displayed.
610 Setting the button clamp centre Y
This function is used to help set the
centre of the button clamp in Y-direc
-
tion. After entering this function, the
machine moves to the current but-
ton clamp centre, after pressing a key
to the front or the rear limit (param.
"024"). The button clamp must be shif-
ted manually.
611 Automatic button clamp opening off
With this function the automatic ope
-
ning of the button clamp after thread
trimming can be switched off. After
the machine has been switched off,
the automatic button clamp opening
function is always activated.
ON - OFF OFF
612
Test function continuous start
ON - OFF OFF