Input
65
Group
Gruppe
Parameter
Parameter
Description
Bedeutung
Setting
range
Set value
800
The function groups and the functions
Programming the Function Keys P, P1
-
P8 and C1-C3 can be released for mani-
pulation (ON) or locked (OFF). If a func-
tion group is suppressed, its parame-
ters cannot be changed until a valid ac-
cess code has been entered. Once a
valid access code has been entered,
the suppression is cancelled until the
machine is switched off.
801
Right of access function group 000
ON - OFF ON
802
Right of access function group 100
ON - OFF ON
803
Right of access function group 200
ON - OFF ON
807
Right of access function group 600
ON - OFF OFF
808
Right of access function group 700
ON - OFF OFF
809
Right of access function group 800
ON - OFF OFF
810 Right of access to keys "P"
,
"P1" - "P8" and "C1" - "C3"
ON - OFF ON
811
Access code
This parameter is used to alter the ac-
cess code. Upon delivery the
machine is set with the access code
"3371"
3371
11.09 Error messages on the display
Following error messages are shown on the control panel display
ERROR:
1 Processor error STACK_OVERFLOW
ERROR:
2 Processor error STACK_UNDERFLOW
ERROR:
3 Processor error UNDEF_OPCODE
ERROR:
4 Processor error PROTECTION_FAULT
ERROR:
5 Processor error ILLEGAL_WORD_OPERAND
ERROR:
6 Processor error ILLEGAL_INSTRUCTION
ERROR:
7 Processor error ILLEGAL_BUS_ACCESS
ERROR:
8 Processor error NMI
ERROR: 10 OTE (Sewing head recognition unit) not attached
ERROR: 11 OTE not programmed (new)
ERROR: 12 OTE check sum error