LANCE
II
SERVICE
MANUAL
CAUTION
Prior
to
starting
any
investigation
of
the
hydraulic
system,
place
the
airplane
on
jacks.
With
the
airplane
on
jacks,
pull
the
emergency
extension
lever
up
and
latch
in
override
position
thus
preventing
the
buildup
of
unnecessary
pressure
on
the
actuating
cylinders
and
connecting
hydraulic
lines
when
the
gear
is
raised
or
lowered
manually.
Failure
to
comply
with
these
instructions
could
result
in
the
buildup
of
sufficient
pressure
to
unlock
the
downlock
mechanism
allowing
the
gear
to
collapse
when
the
wing
jacks
are
removed.
Prior
to removing
the airplane
from
jacks,
push
the
emergency
extension
lever
down,
turn
on
the
master
switch
and
select
gear
down,
observe
that
all
three
green
lights
indicating
the
landing
gear
is down
and
locked
are
energized.
Turn
master
switch
off.
6-3.
TROUBLESHOOTING.
Malfunctions
in
the
hydraulic
system
will
result
in
failure
of
the
landing
gear
to
operate
properly.
When
trouble
develops,
Jack
up
the
airplane
(refer
to
Jacking
Section
II)
and
then
proceed
to
determine
the
extent
of the
trouble.
Table
VI-III
at
the
back
of
this
section,
lists
the
troubles
which
may
be
encountered
and
their
probable
cause,
and
suggests
a
remedy
for
the
trouble
involved.
A
hydraulic
system
operational
check
may
be
conducted
using
Figures
6-1
or
6-2.
When
the
trouble
has
been
recognized,
the
first
step
in
troubleshooting
is
isolating
the
cause.
Hydraulic
system
troubles
are
not
always
traceable
to
one
cause.
It
is
possible
that
a
malfunction
may
be
the
result
of more
than
one
difficulty
within
the
system.
Starting
first
with
the
most
obvious
and
most
probable
reasons
for
the
trouble,
check
each
possibility
and,
in
turn,
by
process
of
elimination,
isolate
the
troubles.
NOTE
If
it
is found
that
the
hydraulic
pump
is
at fault
and
requires
disassembly,
it
is recommended
that
it be
overhauled
by
an
accredited
overhaul
facility.
Pressure
checks
with
adjustments
may
be accomplished
in accordance
with
instructions
given
in
Paragraphs
6-6
thru
6-9.
Issued:
1/3/78
HYDRAULIC
SYSTEM
1H18

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Piper PA-32RT-300T and is the answer not in the manual?

Piper PA-32RT-300T Specifications

General IconGeneral
BrandPiper
ModelPA-32RT-300T
CategoryAircrafts
LanguageEnglish

Related product manuals