LANCE
II SERVICE
MANUAL
TABLE
VI-III.
HYDRAULIC
SYSTEM
TROUBLESHOOTING
(cont.)
Trouble
Cause
Remedy
With
gear
selector
down
and
three
green
lights
on,
gear
unsafe
light
comes
on or
inter-
mittently on.
With
gear
selector
down
and
three
green
lights
on,
pump
motor
circuit
breaker
opens.
With
gear
unsafe
light
on,
pump
operates
on
and
off.
With
gear
unsafe
light
on,
pump
motor
circuit
breaker
opens.
With
override
lever
up,
auto
extension
off
light
fails
to
operate.
Shorted
gear
up
solenoid.
Shorted
gear up
solenoid.
Shorted
gear down
solenoid.
Shorted
gear down
solenoid.
Auto
extension
off
switch
actuator
out
of adjustment.
Replace
solenoid.
Replace
solenoid.
Replace
solenoid.
Replace
solenoid.
Adjust
switch. (Refer
to
Section
VI, Paragraph
6-2
for
switch
loca-
tion)
by moving
mount-
ing
bracket
at attach-
ment slot.
Adjust
switch until
actuator
is closed
when
emer-
gency
gear
handle
is
in override
position
and
open
when
handle
is in neutral.
Auto
extension
off
switch
failed.
Auto
extension
off
flasher
failed.
Replace
switch.
Replace
flasher.
Issued:
1/3/78
HYDRAULIC
SYSTEM
1124

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Piper PA-32RT-300T and is the answer not in the manual?

Piper PA-32RT-300T Specifications

General IconGeneral
BrandPiper
ModelPA-32RT-300T
CategoryAircrafts
LanguageEnglish

Related product manuals