LANCE IISERVICE MANUAL
TABLE
VII-IV. TROUBLESHOOTING
CHART
(LANDING
GEAR)
Trouble
Cause
Remedy
Red gear
unsafe light
out
while gear is in
transit.
Indicator lamp burned
out.
Replace lamp.
Indicator
light
ground
incomplete.
Indicator light circuit
wire broken.
Indicator
light circuit
breaker open.
Check
ground
circuit.
Check wiring.
Reset circuit breaker
and
determine
cause
for
open
circuit
breaker.
Red
gear unsafe
light on
though
gear has
re-
tracted.
One or more up limit
switches failed.
Isolate and replace
switch.
Nose
gear up
limit
switch out of ad-
justment.
Main
gear not
re-
tracting
far
enough
to actuate
switch.
Check gear up adjust-
ment
and readjust
up
limit switch.
Check gear up adjust-
ment.
Red gear unsafe light on
though
gear is down
and locked.
One or
more down
limit
switches
failed.
Isolate
and
replace
switch.
Nose gear
down limit
switch out of adjust-
ment.
Readjust
down
limit
switch.
Issued: