LANCE
II SERVICE
MANUAL
TABLE
VII-IV.
TROUBLESHOOTING
CHART
(LANDING
GEAR)
(cont.)
Trouble Cause Remedy
Red gear
unsafe
light
and
all
green
lights
out.
NOTE:
Ascertain
navi-
gation
lights
are
off (daytime).
Red gear
unsafe light
and
horn
fail
to
operate
when throttle
is
near
closed
and landing
gear
is retracted.
Indicator
lights
circuit
breaker
open.
Light
circuit
wire
broken.
Landing
gear
selector
circuit breaker
open.
Reset
circuit
breaker
and determine
cause
for
open
circuit
breaker.
Check
wiring.
Reset
circuit breaker
and
determine
cause
for open circuit
breaker.
Micro switch
"A"
at
throttle
out of
adjustment.
Micro
switch
"A"
failed.
Warning
horn and
light
circuit wire
broken.
Diode in
circuit between
throttle
switch
"A"
and
light/horn
open.
Adjust
micro switch
"A."
Replace switch.
Check wiring.
Replace
diode.
NOTE:
When
re-
placing
diode,
connect
banded
end
(cathode)
to
terminal
ends of
wires
G2Q
and
G2K
on mounting
block.
Issued:
1/3/78
LANDING
GEAR AND
BRAKE SYSTEM
1L19

Table of Contents