Page #481 background image
Dirty
commutator.
Shorted,
grounded,
or open armature.
Grounded
or
open
field circuit.
LANCE
II SERVICE
MANUAL
TABLE
XI-III.
ELECTRICAL
SYSTEM
TROUBLESHOOTING
(cont.)
uble
Cause
Reme
Trouble
edy
STARTER (cont.)
Motor
fails to
operate. (cont.)
Binding, worn, or im-
properly seated
brush, or brushes
with
excessive
side
play. (cont.)
CAUTION
Do not use coarse
sandpaper
or emery
cloth. After
seating.
clean thoroughly to
remove
all
sand and
metal
particles
to
prevent excessive
wear. Keep motor
bearing free from
sand
or metal
particles.
If commutator
is rough
or dirty, smooth and
polish with number 0000
sandpaper. If too rough
and pitted,
remove
and
turn down. Blow out
all particles.
Remove and replace with
an armature
known
to
be in good condition.
Test, repair if possible
or replace with a new
part.
Low motor and crank-
ing speed.
Worn, rough,
or
im-
properly lubricated
motor or starter
gearing.
Disassemble,
clean,
in-
spect, and relubricate,
replacing ball bearings
if worn.
Same electrical causes
as listed under "Motor
fails to operate".
Same
remedies
listed
for these troubles.
ELECTRICAL
SYSTEM
Issued: 1/3/78
211

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Piper PA-32RT-300T and is the answer not in the manual?

Piper PA-32RT-300T Specifications

General IconGeneral
BrandPiper
ModelPA-32RT-300T
CategoryAircrafts
LanguageEnglish

Related product manuals