RS232 Codes
Planar RPS and Video Controller RS232 User Guide Page | 32
020-1332-00I
PANEL.VOLTAGE Panel Voltage 1514 ? 1-4294967295 String PANEL.VOLTAGE(8)?
PANEL.VOLTAGE(8):48.12
Returns the input voltage of a panel. No 5.1 Yes Yes
POWER.STATUS External Device
Power Status
2701 ? PS#
PSW#
0=OFF
1=ON
POWER.STATUS(PSW2)?
POWER.STATUS(PSW2):"OFF"
Gets the specified device power state. Yes 8.0
10.0
1
Yes No
PS.PRESENT Power Module
Present
1422 ? 1-4 0=NOT_PRESENT
1=PRESENT
2=INVALID
PS.PRESENT(2)?
PS.PRESENT(2):PRESENT
Returns if a power supply module is
detected within the power supply.
Yes 1. x Yes No
PS.STATUS Power Module
Status
1423 ? 1-4 String PS.STATUS(3)?
PS.STATUS(3):0x284A
This command is used for critical health
status of the RPSM; further diagnosis of an
issue may need to be completed at the
factory.
Output will be in a hexadecimal format.
Converting to binary and noting the
position starting at the right (0 position)
and noting the position of the non-zero
character(s) up to the last (15) will indicate
which faults were seen.
Note: For the example shown, 284A, the
hex value coverts to 0010 1000 0100 1010.
This indicates that 1, 3, 6, 11, and 13 were
noted as fault conditions.
0 = Unspecified fault
1 = Communication Memory Fault
2 = Module temperature may have
exceeded the maximum
3 = VAC is below minimum
4 = IDC is above maximum
5 = VDC is above maximum
6 = Module DC is off
7 = Module is performing previously
requested actions
8 = Unspecified fault
9 = Unspecified fault
10 = Fan failure
11 = Power status
12 = Unspecified Fault
13 = VAC fault warning
14 = IDC fault or warning
15 = VDC fault or warning
0xFFFFFFFF = Module not present, invalid
or off
Yes 1.x Yes No