EasyManua.ls Logo

Planmeca ProSensor User Manual

Planmeca ProSensor
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
10019763_11
Digital Radiography System
EN
user's manual
Question and Answer IconNeed help?

Do you have a question about the Planmeca ProSensor and is the answer not in the manual?

Planmeca ProSensor Specifications

General IconGeneral
Sensor TypeCMOS
Sensor SizesSize 1, Size 2
ConnectionUSB
Image ResolutionUp to 20 lp/mm
ResolutionUp to 20 lp/mm
CompatibilityPlanmeca imaging software
DimensionsVaries by size
WeightVaries by size

Summary

Introduction to Planmeca ProSensor

System Symbols and Related Manuals

Safety Precautions for System Operation

System Requirements for Planmeca ProSensor

Planmeca ProSensor ControlBox Indicator Light

Before Exposure Procedures

Positioning the Patient

Instructions for positioning the patient and applying a protective lead apron before exposure.

Positioning the Sensor

Guidance on selecting and connecting the sensor and using the paralleling technique.

Selecting Exposure Values

Guidance on selecting digital imaging modes and exposure times based on patient and tooth type.

Capturing Intraoral Images

Capturing Single Intraoral Images

Steps to initiate and perform single intraoral image capture using the Planmeca ProSensor.

Capturing Images into a Study Template

Procedure for capturing multiple images into predefined study templates for organized patient records.

Image Quality Control Procedures

Quality Check Using SMPTE Test Pattern

Procedure for verifying image quality using the SMPTE test pattern for monitor settings and checks.

Using the Sensor Holders

Cleaning and Maintenance

Cleaning Surfaces

Methods for cleaning the exterior surfaces of the Planmeca ProSensor system components.

Cleaning Sensors and Cables

Guidelines for cleaning and disinfecting the sensors and cables, including precautions.

Cleaning Sensor Holders

Instructions for cleaning the sensor holders, referring to the supplied manual.

Cleaning Planmeca ProSensor ControlBox

Procedure for cleaning the Planmeca ProSensor ControlBox with a soft cloth.

Disposal of Planmeca ProSensor

Technical Specifications

Sensor Specifications

Details on sensor type, dimensions, resolution, cable length, and expected service life.

Supported Operating Systems

List of compatible client and server operating systems for the Planmeca ProSensor system.

ControlBox Specifications

Technical details for Ethernet and USB ControlBoxes, including dimensions, power, and cables.

Operating and Environmental Conditions

Specifies required operating and environmental conditions for the Planmeca ProSensor system.

Appendix A: Exposure Values for Planmeca ProX

Default Exposure Values

Default exposure values for short and long cone exposures when the unit is switched on.

Preprogrammed Settings Values

Preprogrammed exposure values (time/kV/mA) for different exposure regions and modes.

Related product manuals