22
DIGITAL TEMPERATURE CONTROLLER
The PH Series has three Digital Temperature Controllers to manage the temperatures for the
Primary Heaters (Iso (A), Poly (R)) and the Heated Hose. The Hose Heater Controller is
programmed different from the Iso (A) and Poly (R) Controllers and therefore not
interchangeable with them.
WARNING! Do not turn the Temperature Controllers ON until
the Proportioner Purging procedure is complete and the
Primary Heaters and Heated Hoses are filled with material.
1. Ensure Main Power (Q, page 11) is ON,
Control Power (S, page 11) is ON, and 01
Display light is lit.
2. Press and release button. The display will
read SP1.
3. Press and release or button to display the current material temperature set-point.
4. Press and hold the or to increase or decrease the material temperature set-point to
the desired value as determined by the material supplier or application conditions.
5. Press and release and together to return to the actual material temperature in the
Primary Heater/Hose Heater.
WARNING! The Controllers are factory programmed and are
not field re-programmable. If a problem is encountered,
contact your PMC Distributor. Do not attempt to change any
of the programmed parameters. Do not substitute a
Controller from an alternate supplier as its use may result in
equipment damage and/or bodily injury.
NOTE! The Temperature Controller normally displays the actual material
temperature. When lit, the “01” display in the upper left indicates power is
sent to the designated heating system. The “01” display goes out when the
material temperature has reached its set-point. The “01” display will
continue to cycle on and off indicating the Controller is maintaining the
material temperature set-point.