10.43
ELECTRICAL
10
Starter System Test Flow Chart, cont’d.
No
Yes
No
Test B (from previous page)
Continued from previous page
Voltage Drop Testing
Reconnect the solenoid. Connect the tester black
.
lead to the battery positive and the red lead to the
solenoid end and actuate the starter. Reading
should be less than .1 V D.C
Clean the battery-to-solenoid cable ends
or replace the cable.
Connect the black tester lead to solenoid end of
battery-to-solenoid cable. Connect red tester lead
to solenoid end of solenoid-to-starter cable.
Reading should be less than .1 V D.C.
Yes
Replace the starter solenoid.
Connect the black tester lead to the solenoid end
of the solenoid-to-starter cable. Connect the red
tester lead to the starter end of the same cable.
The reading should be less than .1 V D.C.
No
Clean the solenoid-to-starter cable ends
or replace the cable.
Yes
If all of these indicate a good condition, yet the starter still fails to turn, the starter
must be removed for static testing and inspection.