© Copyright Polaris Industries Inc.
SPN COMPONENT
FMI CONDITION CODE
18 Data Valid But Below Normal Operating Range - Moderately Severe
Level
P17AF
8014
Battery Charger
18 Data Valid But Below Normal Operating Range - Moderately Severe
Level
P0761
31 Condition Exists P0762
65559 CAN1 Bus Hardware
11 Root Cause Not Known P1130 / U2101
31 Condition Exists C1130
65613
ETC Accelerator Position Sensor
Correlation
2 Data Erratic, Intermittent Or Incorrect P1135
516125 CAN 1
9 Abnormal Update Rate U25E9
516178
Idle Engine speed
19 Received Network Data In Error U25C0
520129 ABS Low Pressure Feed Circuit 1
31 Condition Exists C1012
520130 ABS Low Pressure Feed Circuit 2
31 Condition Exists C1013
520131
ABS Valve Relay
12 Bad Intelligent Device Or Component C2420
520132
ABS Pressure Sensor Supply Out
of Range
31 Condition Exists C2423
520133 ABS Internal Pressure Sensor
2 Data Erratic, Intermittent Or Incorrect C2439
12 Bad Intelligent Device Or Component C2424
520134
ABS Motor Supply Failure
31 Condition Exists C2425
520137
ABS Manually Disabled
31 Condition Exists C2433
520140 ABS Internal ECU Failure
12 Bad Intelligent Device Or Component C2437
520141
CAN1 Bus Wiring
31 Condition Exists C2438
520152
ABS Solenoid (Rear Left In)
31 Condition Exists C1324
520153
ABS Solenoid (Rear Left Out)
31 Condition Exists C1325
520194
Throttle Release Signal
2 Data Erratic, Intermittent Or Incorrect P1553
3 Voltage Above Normal, Or Shorted To High Source P1555
4 Voltage Below Normal, Or Shorted To Low Source P1554
7 Mechanical System Not Responding Or Out Of Adjustment P1552
520198 Throttle Position Sensor 2
0 Data Valid But Above Normal Operational Range - Most Severe Level P1223
1 Data Valid But Below Normal Operational Range - Most Severe Level P1222
3 Voltage Above Normal, Or Shorted To High Source P0223
4 Voltage Below Normal, Or Shorted To Low Source P0222
10 Abnormal Rate Of Change P0220
13 Out Of Calibration P1220
520201
Overheat Indicator Lamp
3 Voltage Above Normal, Or Shorted To High Source P1656
4 Voltage Below Normal, Or Shorted To Low Source P1657
5 Current Below Normal Or Open Circuit P1655
520202
Canister Purge Valve
3 Voltage Above Normal, Or Shorted To High Source P0443
4 Voltage Below Normal, Or Shorted To Low Source P0445
5 Current Below Normal Or Open Circuit P0444
520203
Front Wheel Back Drive (Active
Descent System)
3 Voltage Above Normal, Or Shorted To High Source P1686
4 Voltage Below Normal, Or Shorted To Low Source P1687
5 Current Below Normal Or Open Circuit P1685
520204 Fuel Correction Front
15 Data Valid But Above Normal Operating Range - Least Severe Level P0172
GENERAL INFORMATION

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Polaris RZR PRO R 4 and is the answer not in the manual?

Polaris RZR PRO R 4 Specifications

General IconGeneral
BrandPolaris
ModelRZR PRO R 4
CategoryOffroad Vehicle
LanguageEnglish

Related product manuals