3 Technical specifications
3.1 Homologations
3.1.1 Safety, Performance & Quality
This boiler has been assessed by an appropriate Notified Body and shown
to meet the requirements of all Directives and Regulations as applicable.
These Directives and Regulations lay down requirements for the safety
and efficiency of the appliance, together with its design, construction and
use of materials. They also require the production process to be covered
by an approved and monitored system of quality assurance.
3.1.2 Certifications
Tab.1 Certifications
CE certificate number 0085CS0215
NOx class 6
Boiler type C
13
, C
33
3.1.3 Gas category
Tab.2 Gas category, type and supply pressure
Gas category Gas type Supply pressure (mbar)
I
2H
G20 20
3.1.4 Standards
Codes of Practice — refer to the most recent version
Tab.3 In GB the following Codes of Practice apply:
Standard Scope
BS 6891 Gas Installation.
BS 5546 Installation of hot water supplies for domestic purposes.
BS
EN
12828
Heating systems in buildings.
BS EN
12831
Heating systems in buildings — Calculation of load.
BS EN
14336
Installation & commissioning of water based heating sys
tems.
BS 6798 Installation of gas fired hot water boilers.
BS
5440
Part 1
Flues.
BS 5440
Part 2
Ventilation.
BS 7074 Expansion vessels and ancillary equipment for sealed wa
ter systems.
BS 7593 Treatment of water in domestic hot water central heating
systems.
BS 4814 Specification for Expansion Vessels using an internal dia
phragm, for sealed hot water systems.
IGE/UP/
7/1998
Guide for gas installations in timber framed housing.
3 Technical specifications