EasyManuals Logo

Potterton Assure System Series User Manual

Potterton Assure System Series
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #67 background imageLoading...
Page #67 background image
© Copyright
All technical and technological information contained in these technical instructions, as well as any drawings and technical
descriptions supplied, remain our property and shall not be multiplied without our prior consent in writing. Subject to alterations.
3.
Min. both models 0.34 kg/h
Max. 18 model
Max. 24 model
1.37 kg/h
1.83 kg/h
Measure the gas rate (LPG)
Tab.23 Characteristics of combustion
Potterton Assure System
% (maximum)
% (minimum)
10.0 + 0.1 – 0.5
9.3.12 Gas valve
7.4.1
Check the operational (working gas inlet pressure and
gas rate)
18 LPG 19.4 kW CH Pnc (Condensing)
24 LPG 25.8 kW CH Pnc (Condensing)
4.1 General description
Tab.15 The boiler is set to give a maximum output of :-
The boiler is factory set for use on
Propane (G
31
).
Potterton Assure System
Gas council numbers
3.1.3 Gas category
Tab.2 Gas category, type and supply pressure
Gas category Gas type Supply pressure (mbar)
I
I
2H
3P
G31
37
3.2.1 Technical information
14 Appendix
14.3 Differences for LPG models
Important
The information in this section details the differences between
LPG models and equivalent Natural Gas versions
18 LPG
10.5 + 0.5 – 0.1
LPG
41 592 96
24LPG
41 594 16
CO
2
% (maximum)
% (minimum)
9.8 + 0.1 – 0.5
10.3 + 0.5 – 0.1
CO
2
Case On
Case Off
67

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Potterton Assure System Series and is the answer not in the manual?

Potterton Assure System Series Specifications

General IconGeneral
BrandPotterton
ModelAssure System Series
CategoryBoiler
LanguageEnglish

Related product manuals