POWER ELECTRONICS
SD700 – TOUCH-GRAPHIC DISPLAY
APPLICATION MANAGEMENT
25
2.4. Parameter Setting
There are two kinds of parameters in the drive according to the data type:
Parameters with adjustable numerical values:
They are parameters, the values of which are numerical value. These values can be float or
integer.
Parameters with selectable configuration options:
They are parameters, the values of which are configuration options. These options are
enumerated internally for the management of the drive, but the user can only see the associated
labels, that means, the texts that represent the possible configuration options.
All of the programmable parameters are grouped in ‘G Configuration group’ menu, and additionally,
the most common parameters to configure the drive are also available in ‘V5 Programmable
parameters’ from ‘V Visualization’ menu. The user can set the parameters from the subgroup where
the specific parameter are included in ‘G Configuration group’ menu and from subgroup ‘V5
Programmable parameters’ in ‘V Visualization’ menu, if that parameter is included on it.
Also, the user can adjust the parameters from the ‘Custom visualization’ menu, whenever the desired
parameter has been added to the parameter list by him before.
To adjust a parameter, the user should follow the next steps:
1. Access to the parameter group where the desired parameter is included by tapping on the
corresponding menus in the visualization area.
2. Once the parameters of the group are shown in the screen, search the desired parameter in the
rows of the ‘Description’ column.
3. After finding it, tap on the value cell located in the same row of the desired parameter.
4. After tapping on the corresponding cell, it will appear a configuration dialogue window where the
parameter is set. Depending on the parameter type (numerical value or configuration option), the
dialogue window is different.
In this point, the user should consider the following:
o Some parameters cannot be modified when motor is running.
These ones are only adjustable when the motor is completely stopped (led RUN is OFF).
If the motor is running and the user taps on the value cell of a non-adjustable parameter
during run, a notification message will appear with the text: ‘Parameter can’t be modified.
Motor must be OFF’. In this case, the user should wait for the motor is completely
stopped and try it again.
o Most of the parameters are affected by the parameter lock.
If the user tries to set one of these parameters and taps on the value cell, a notification
message will appear with the text: ‘Parameter can’t be modified. Parameter lock
enabled’. In this case, the user should unlock parameters and try it again.
For additional information, see section ‘2.5. Parameters Lock’.
o Some parameters are not adjustable.
No effect is produced when the user tap on the value cell of a non-adjustable parameter.
These parameters are the visualization parameters grouped in ‘V Visualization’ menu
and the configuration parameters from 1 to 6 included in group ‘G13 Fault history’ inside
the ‘G Configuration group’ menu.