9.4 About Failsafe
9.4.1 What is failsafe mode?
All Dante hardware modules use software loaded from Flash memory as part of their operation.
As with any storage device, it is possible to corrupt the data on the Flash part, potentially rendering it unusable, if there are interruptions
while writing to the Flash device.
By far the most common way for this to occur as with other Flash devices is by losing power to the Dante-enabled device in the middle
of a rmware upgrade.
To provide recovery from this event, Dante hardware modules have a special protected part of the Flash memory that will run in the
event the main part is corrupted.
When this is run, the module is in “failsafe mode”, and will wait for a recovery image to be provided by the Firmware Update Manager.
9.4.2 How do I tell if a device is in failsafe mode?
By viewing the device in the Dante Controller.
A Dante device that is in failsafe mode will appear with its default device name in red in the default network grid view of Dante Controller
(versions 3.1.x and above).
9.4.3 How do I recover from failsafe mode?
To restore a device that has entered failsafe mode, use the Dante Firmware Update Manager ‘Failsafe Recovery’ option.

Other manuals for powersoft T Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the powersoft T Series and is the answer not in the manual?

powersoft T Series Specifications

General IconGeneral
Brandpowersoft
ModelT Series
CategoryAmplifier
LanguageEnglish

Related product manuals