8. Install the actuator tube into the incline platform mounting bracket. Hold the jack screw
from turning while inserting the actuator tube into the mounting bracket. Secure with
clevis and hitch pins.
9. If the Lift Motor actuator tube has turned during the installation process (which changes
the incline reference gap distance) re-calibrate the Lift Motor, see "Lift Motor Cal-
ibration" on page24.
10. Return the treadmill to the upright position.
11. Level the treadmill.
12. Install hood and all removed covers and trim.
13. Connect the power cord and Switch the input power to ON.
14. Verify the treadmill incline operation through the full range of motion. Do the "Hardware
Validation - Diagnostic Tests (51765761)" on page13 - INCLINE TEST diagnostic test.
15. Verify treadmill operation (see "Operation Verification" on page8) and return to service.
See Also
"Replacement Procedures" on page29
"Lift Motor Calibration" on page24
(Undefined variable: TRM700-16Base.ServiceManualTitle)