Press and hold the reset key for at least 6 seconds and look at the error log again. This time look for
any NEW errors displayed resulting from the verification test indicating that the unit
Operation Verification Checklist
Check, record, and then clear any errors in the error log.
Verify that all LEDs function properly during the Hardware Validation Tests.
Verify that all keys on the keypad function properly during the Hardware Validation Tests.
Verify that the heart rate functions normally and displays a valid heart rate.
Verify the running belt drive system functions properly throughout the minimum to
maximum range of control. All drive system components (deck, belts, rollers, IFT) are free of
excessive noise, vibrations, or smells
Verify the Incline A/D value is approximately 6000+/-500 at 0% incline; the incline operates
within the complete range of the lift when the or keys are pressed and is free of
excessive noise or vibrations.
The STOP button stops the running belt from moving.
Pulling the ESTOP cord stops the running belt from moving.
Check for new errors that may have been recorded in the error log during operation
verification of the treadmill.