© Precor Incorporated, Unauthorized Reproduction and Distribution Prohibited by Law Page 41
- The console is solely responsible for commanding the color changes of the Motor
Controller LED (MCL) and the Active Status LED (ASL).
- The console will attempt to reset all errors originating from the Motor Controller, with
exceptions mentioned below in the error list.
- For an error state that prevents the treadmill from starting, at banner, the message bar
will scroll “PLEASE USE ANOTHER TREADMILL.”
The error log will contain the following pieces of information for each error captured:
Error code
Hours
Odometer
Motor amps
Line amps
Line voltage
Motor Controller buss voltage
Error Code Table
The following is a list of the error codes currently assigned to the TRM 800-V.2:
Table 1: TRM800.V2 Error Code
Key Depressed at Power Up
Line Frequency out of Acceptable Range
Watchdog (Upper PCA) Low Voltage
Watchdog (Lower PCA) Low Voltage
Over - buss voltage/ DC link voltage too high
A.C. Input Voltage Too Low
DB Resistor thermal I2t trip
DB Resistor thermal switch open
Motor will not start/no motor movement detected
Lower Drive hardware error
Too Much Drive Motor Current
Temperature Too High/Drive Electronics
Excessive AC Input Current/ Instantaneous
Excessive AC Input Current/ Circuit Breaker Trip Prevention
E-STOP Upper State vs. Lower State Mismatch
Lift Position Value Out of Range