DS600 Non-Ferrous Double Sheet Detector
This document is confidential and proprietary. No part of this document may be disclosed in any manner
to a third party without the prior written consent of Prime Controls, Inc.
202177 16 Revision M
Table 5 – Model DS600 Single/Double Sensing
SW 2
LED
Output
LED
Output
<= Single/Double Threshold
> Single/Double Threshold
Symbols:
< is less than, > is greater than, <= is less than or equal to, >= is greater than or equal to.
Table 6 – Models DS600P and DS600PC Single/Double Sensing
SW 2
LED
Output
LED
Output
Output*
* Only if switch 3 ON.
The part present sensing mode may be used to insure that a second component is present on
an assembly. A typical application would be to insure that a captive nut is in place on an
assembly. The logic of part present sensing is reversed as compared to single/double sensing.
Here the stronger signal, indicating more material, is the accepted condition while in
single/double sensing the stronger signal indicates the unwanted condition of too much material.
Table 7 shows the response of all DS600 model ACCEPT and REJECT LEDs and ACCEPT,
REJECT, and AUX control outputs to various gauge signal levels and switch 2 settings for part
present sensing.