DS600 Non-Ferrous Double Sheet Detector
This document is confidential and proprietary. No part of this document may be disclosed in any manner
to a third party without the prior written consent of Prime Controls, Inc.
202177 17 Revision M
Table 7 - Part Present Sensing All Models
Gauge Signal
SW 2
ACCEPT
LED
ACCEPT
Output
REJECT
LED
REJECT
Output
< No-metal Threshold
OFF
OFF
OFF
OFF
ON
ON
OFF
OFF
RED
OFF
>= No-metal Threshold
OFF
OFF
OFF
RED
OFF
<= Part Present Threshold
ON
OFF
OFF
RED
OFF
> Part Present Threshold
OFF
GREEN
ON
OFF
ON
ON
GREEN
ON
OFF
ON