540876_A_PUB_DATE_1_FEB_2012.DOC PROGRAMOVACÍ MANUÁL 49
PROGRAMMING
Attention!
It’s not recommended to program a spin sequence just after a Static Drain Sequence.
At a Static Drain sequence, the garments are not distributed around the drum while the water is drained.
When the spin sequence starts, the garments are a big imbalance and the imbalance (tilt) function will be
activated.
THE REVERSING DRAIN SEQUENCE
The drum is reversing while the water is drained.
Menu Item Default Info Limits
Drain Valve 1 Only available on washing machines with both : a
normal Open and normal Closed Drain valve.
1 - 2
RPM - The suggested RPM depends on the machine Type. See table 3.5.B
On Time 12 sec The mechanical action, motor On Time.
(The suggested default values can be adjusted at the Initialization
menu)
1 - 99 sec
Off Time 3 sec The mechanical action, motor Off Time.
(The suggested default values can be adjusted at the Initialization
menu)
1 - 99 sec
Time 0.5 Min The Static Drain Sequence Time.
(for 0 Minutes the Static Drain sequence will be skipped)
(programmable in steps of 0,5 Minutes)
0 - 15,0 Min
Exit Return to Edit Program Menu.
!
Drain
|
Extract
|
No Drain
|
Static Drain
|
Reversin
g
Drain