80 PROGRAMOVACÍ MANUÁL 540876_A_PUB_DATE_1_FEB_2012.DOC
BASIC Diagnostic Wash program
Sequence Supply Inlet
Temp. Level Wash action Time R.P.M.
Wash 2=30” 2-3-6-8 40°C NL A=12“ R=3“ 6 min W
Step 1
Drain - - - - - 30 s D
Rinse 1 - 1-2-7 - NH A=12“ R=3“ 1,5 min W
Step 2
Spin - - - - - 1 min L
Final Rinse 3=30 4-7 - NL A=12“ R=3“ 2 min W
Step 3
Spin - - - - - 4,5 min H
Slowdown - - - - - 1 min -
Tumble - - - - A=12“ R=3“ 30 s W
Error messages :
If the computer detects some problem during the Diagnostic Help Program, a diagnostic error message is
generated.
Check also the Error Log List in the Service-menu.
Check the error handling and explanation of the error messages.