11.2 Fault Alerts
Error description Cause Solution Personnel
Red LED indicator
(fault indicator) lights
up and the pump stops
The fluid level in the feed tank has reached
"low liquid level stage 2
"
Fill the feed tank Instructed
personnel
The multifunctional switch is not turned to
"Extern"
but an external cable is connected
and the pump has the identity code feature
"Controller type" - "1" "with lock".
Either turn the multifunc‐
tional switch to "Extern"
or remove the Extern
cable from the pump
Technical
personnel
11.3 Warning Alerts
Error description Cause Solution Personnel
Yellow LED indicator (warning
indicator) lights up
The fluid level in the feed tank has
reached "low liquid level stage 1
"
Fill the feed tank Instructed
personnel
11.4 All Other Faults
Please
contact the responsible ProMinent branch or representative!
Troubleshooting
36