Type PP, NP PV TT, SS
0232 1023129 1023129 483975
All HV types - 1019364 -
* 11-part
Product Part no.
Fault indicating relay Beta® b: 1028839
Fault indicating / pacing relay
option Beta® b:
1028840
Product Part no.
Varistor: 710912
RC Gate, 0.22 µF / 220 Ω: 710802
Further information on spare parts, accessories and options can be
found in:
n the exploded drawings
n the identity code
n the "General Operating Instructions on ProMinent
®
solenoid
dosing pumps
".
n the ProMinent
®
Equipment catalogue
14.5 Retrofitting Relays
WARNING!
Risk of electrocution
When retrofitting relays, there is access to live parts
– Disconnect the pump from the mains power supply
prior to commencing work
1 - Relay board, compl., with 2 fixing screws
1 - Relay cable, compl., with connector
1 - Seal
CAUTION!
Pump can be damaged
The
pump circuit board can become damaged when the
opening is broken open.
– When breaking open the opening, avoid pushing the
screwdriver deep into the pump foot.
Relays
Interference suppression aids
Further sources of information
Scope of delivery
Breaking push-through opening
Appendix
75