24
2 Device Identification / Identity Code
D1C A
Please enter the identity code of your device here.
D1C DULCOMETER
®
Controller Series D1C
W Wall mounting
D Control panel installation, 96 x 96 mm
Operating voltage
0 230 V 50/60 Hz
1 115 V 50/60 Hz
2 200 V 50/60 Hz (control panel installation only)
3 100 V 50/60 Hz (control panel installation only)
4 24 V AC/DC
Measured variable
B Bromine (0.1...13 mg/l) (3rd quarter 2001)
C Chlorine (0...0.5/2/10/20 mg/l)
L Conductivity (0…20/200/2000 µS/cm; 0…20/200 mS/cm)
P pH (0...14 pH)
R Redox (-1000...1000 mV)
H Hydrogen peroxide (1…20; 10…200; 100…2000 mg/l)
S Standard signal (0/4-20 mA)
A Peracetic acid (10…200; 100…2000 mg/l)
D Chlorine dioxide (0...0.5/2/10/20 mg/l)
Z Ozone (0...2 mg/l)
X Dissolved Oxygen (0.1...10/20 ppm)
T Temperature (0...100 °C)
Connection of measured variable
1 Terminal, standard signal 0/4-20 mA (signal converters necessary for controllers
with measured variable connection, standard signal 0/4-20 mA
2 SN6 connector for P or R
3 Terminal for L
4 Terminal PT 100 for T
5 Terminal mV for P or R
Correction variable
0 None
1 pH for chlorine
2 Temperature for P, D, H, A or L via terminal
3 Temperature for P, D, H, A or L via standard signal 0/4-20 mA
4 manual temperature entry for P, H, A or L
Feedforward control
0 None
1 Flow as standard signal 0/4-20 mA
2 Flow as frequency 0 - 500 Hz
3 Flow as frequency 0 - 10 Hz
Control input
0 None
1 Pause
Signal output
0 None
1 Standard signal 0/4-20 mA measured value
2 Standard signal 0/4-20 mA controlled variable
3 Standard signal 0/4-20 mA correction variable
42 standard signal outputs 0/4-20 mA, freely programmable (not for H, A)
Power control
G Alarm and 2 limit value relays
M Alarm and 2 solenoid valve relays (pulse length control)
R Alarm relay and actuator with feedback
Pump control
0 None
2 Two pumps
Control characteristic
0 None
1 Proportional control
2 PID control
Log output
0 None
Language
D German (E, F, N)
E English (D, F, N)
F French (D, E, N)
I Italian (D, F, S)
N Dutch (D, E, F)
S Spanish (D, I, F)
P Polish (D, E, A)
A Swedish (D, E, P)
B Portuguese (E, S, F)
U Hungarian (P, A, E)
G Czech