R
December 1, 2011
Page31
Santa Fe NZ Pellet Stove
7068-114B
Reference Materials
8
A. Commissioning
Oncetherehasbeeninstalleditwillneedtobetested
andcommissionedforcorrectrunningandtocomplywith
theNZcleanairregulations.Todothisyoumayneedto
altertherotaryselectorswitchonthetopofthecontrolbox
toachievethecorrectMagnahelicreading,withtheunit
runningonhigh(0.11inchesWC).
ToadjusttheMagnahelicofthereyouneedtoadjustthe
rotaryswitchsettingonthecontrolbox.
Dothispriortostartingthere
• Unplug/depowertheappliance.
• Using7/16”or11mmwrenchorsocket,loosenthe
threenutsthatholdtherightsidepanelinplace.You
donotneedtoremovethenuts.Removesidepanel
byliftingupandout.
• Removethecontrolboxretainerbracket.
Startthereonhigh(see“StartingYourFirstFire”onpage
9)andletitrunforatleast15minutes
• Unplug/depowertheappliance(thiscanbedone
evenwhenthereishotforashortperiod).
• Liftcontrolboxoutofthejunctionbox
• Usingasmallatheadscrewdriverturntherotary
switchuntilthedesirednumberisshowingonthe
dial,(defaultpositionis2).Thisaltersthecombustion
fanspeedandhencetheMagnahelicreading.This
shouldincreasereadingsfromposition1(lowest)to
position7(highest).Position0innotused.
• Reinstallcontrolboxandplugtheappliancebackin.
Oncethepowerisreappliedtherewillgobackthrough
itsstart-upprocess.Youwillneedtowaitatleast10
minutestocheckiftheMagnahelicisnowcorrect.Ifnot
repeattheprocess.Experiencewillhelpjudgethecorrect
settingfortheinstallation.
E
When describing the location
of a component, it is always AS
YOU FACE THE FRONT OF THE
APPLIANCE.
1. Control Box
a.Thecontrolboxislocatedontheupperrightsideof
theappliance,behindtherightsidepanelandabove
thejunctionbox.
b.Thereisalightlocatedinsideofthecontrolbox.The
internallightwillturngreenwhentheappliancehas
reachedatemperatureof200°F(93°C)intherepot
andwillturnredwhenitreaches600°F(315°C).
c.Thereisalsoaninternalbluelightlocatedinthecontrol
box.Whenyouplugintheappliancethebluelightwill
automaticallystartblinking.FormodelSANTAFEthe
bluelightshouldash6timesevery10secondsfor
therst60secondsafterpowerup.
2. Convection Blower
Theconvectionblowerismountedatthebottomrearofthe
appliance.Thereare2impellers,oneoneachsideofthe
motor.Theconvectionblowerpushesheatedairthrough
theheatexchangesystemintotheroom.
3. Exhaust Blower
Theexhaustblowerismountedontherightsideofthe
appliance.Theexhaustblowerisdesignedtopullthe
exhaustfromtheapplianceandpushitoutthroughtheue
system.
4. Feed System
Thefeedsystemislocatedontherightsideofthe
applianceandcanberemovedasanentireassembly.
Theassemblyincludesthefeedmotor,mountingbracket,
bearingandfeedspring(auger).Thehollowfeedspring
(auger)pullspelletsupthefeedtubefromthehopperarea
anddropsthemdownthefeedchuteintotherepot.
5. Firepot
Therepotismadeofhighqualityductileironandhas
acleaningpull-outrod.Theooroftherepotopensfor
cleaningwhenyoupullouttherod.Besurethattheoor
returnstoacompletelyclosedpositionoryourappliance
willnotoperateproperly.
B. Component Function