EasyManua.ls Logo

Queclink GL300 - Command and Acknowledgement; Quick Start Setting

Queclink GL300
90 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
GL300 @Tracker Air Interface Protocol
3.2. Command and Acknowledgement
3.2.1. Quick Start Setting
The command AT+GTQSS is used to set the GPRS parameter and backend server information in
one command if all these settings are within 160 bytes, otherwise use AT+GTBSI and
AT+GTSRI in two steps.
AT+GTQSS=
Example:
AT+GTQSS=gl300,cmnet,,,4,,,116.226.44.17,9001,116.226.44.16,9002,+8613812341234,0,1,
,,0001$
Parameter Length (byte) Range/Format Default
Password 4 – 6 ‘0’ – ‘9’, ‘a’ – ‘z’, ‘A’ – ‘Z’ gl300
APN <=40
APN user name <=30
APN password <=30
Report mode 1 0 – 6 0
Reserved 0
Buffer enable 1 0|1|2 1
Main server IP/domain
name
<=60
Main server port <=5 0 – 65535 0
Backup server IP <=15 0.0.0.0
Backup server port <=5 0 – 65535 0
SMS gateway <=20
Heartbeat interval <=3 0|5 – 360min 0
SACK enable 1 0|1 0
Reserved 0
Reserved 0
Serial number 4 0000 – FFFF
Tail character 1 $ $
<Password>: The valid character of password is ‘0’-9’, ‘a’-‘z’, ‘A’-‘Z’. The default value is
“gl300”.
<APN>: Access point name (APN).
<APN user name>: the GPRS APN user name. If the parameter field is empty, the parameter
will be cleared.
<APN password>: the GPRS APN password. If the parameter field is empty, the parameter
will be cleared.
<Report mode>: Supports report modes as following:
0: Stop reporting.
1: TCP short-connect preferred mode. The connection is based on TCP protocol. The
TRACGL300AN001 - 12 -
Queclink
Confidential

Other manuals for Queclink GL300

Related product manuals