GL300 @Tracker Air Interface Protocol
3.2.2. Bearer Setting Information
The command AT+GTBSI is used to set the GPRS parameter.
AT+GTBSI=
Example:
AT+GTBSI=gl300,cmnet,,,,,,,0002$
Parameter Length (byte) Range/Format Default
Password 4 – 6 ‘0’ – ‘9’, ‘a’ – ‘z’, ‘A’ – ‘Z’ gl300
APN <=40
APN user name <=30
APN password <=30
Reserved 0
Reserved 0
Reserved 0
Reserved 0
Serial number 4 0000 – FFFF
Tail character 1 $ $
The acknowledgement message of AT+GTBSI command:
+ACK:GTBSI,
Example:
+ACK:GTBSI,1A0102,135790246811220,,0002,20100310172830,11F0$
Parameter Length (byte) Range/Format Default
Protocol version 6 XX0000 – XXFFFF,
X{'A'-'Z','0'-'9'}
Unique ID 15 IMEI
Device name 20
Serial number 4 0000 – FFFF
Send time 14 YYYYMMDDHHMMSS
Count number 4 0000 – FFFF
Tail character 1 $ $
TRACGL300AN001 - 15 -