Specific functions of model 0985-0986 with AQUILA PID
Filling Timeout
If the boiler filling takes longer than 120 seconds, the machine generates an alarm
with an intermittent acoustic warning.
This condition may occur if the machine is switched on for the first time, with the
boiler completely empty.
Switch the machine off, then on again to restart the filling.
If the problem persists, make sure there are no water leakages or clogging in the
hydraulic circuit.
No water in the tank
If the water in the tank drops below minimum level, the machine generates an
alarm with an intermittent acoustic warning. To exit from alarm condition, it is
sufficient to fill the tank.
When the machine is in alarm condition due to lack of water in the tank, the boiler
continues to heat and the water level can be topped-up. This is also possible
when the heating is interrupted due to lack of water in the boiler.
Dosing the coffee if there is no water in the tank
If during coffee delivery there is insufficient water in the tank, the machine only
generates an alarm after the delivery terminates.